Description
THE BREEZEIN SERIES
Characteristic
Gentle Breeze
Hotel Model Available
4 Easy Design
4-step Self-cleaning
Inverter AC
Extreme Cooling & Heating
A++ Energy Efficiency
GENTLE BREEZE
Gentle Breeze Cooling without Direct Wind
Enjoy more comfortable cooling with Gentle Breeze mode. Up to 1,422 micro-holes create a soft laminar airflow. Avoid harsh, direct cold draft and unlock superior refreshment.
Soft and Comfortable Wind with Gentle Breeze Blades & Micro Holes
S09P5S1/S09P5S0/ S12P5S1/S12P5S0: 13 Gentle Breeze Blades, 1066 Micro-holes; S18P5S0 : 16 Gentle Breeze Blades, 1312 Micro-holes; S24P5S0: 18 Gentle Breeze Blades, 1476 Micro-holes
Air Flow Comparison
DEEP CLEAN
4 Steps Auto Clean
From dewing, frosting, sterilizing to drying. Deep Clean utilizes water molecules in the air to clean away dust, dirt, and other impurities. The auto program is efficient, easy, and a superior way to enjoy cleaner air – just click the button.
SMART AIRFLOW
Shower Style Cooling
Directed-upward airflow showers down from the ceiling to create immersive cooling.
Rising Style Heating
Warm and humidity-optimized airflow rises back up from the floor evenly.
ENERGY SAVING
3 Energy-saving Levels
A++ Energy Efficiency
A++ Efficient and economical to heat or cool your home with high energy efficiency.
Eco Mode Power Saving & Environment Protection
Hit Eco Mode for efficiency-optimized 26°C program. Be kind on the environment,
save electricity bills and maintain a tight temperature range.
OPTIMIZED INSTALLATION & MAINTENANCE
Easy Assembly
Less Parts, Less Screws, makes it friendly to assemblers. Full Buckle Design with No Screw. 20”= Disassembly + Assembly, Assembly Efficiency Increased by 9.4%.
Easy Disassembly and Cleaning
Cleaning and disassembling an air conditioner is not as complicated
as imagined, and it can be completed in three steps.
Fast Installation
Fast installation simple and solid bracket with a convenient access for an easy installation.
Quick Replacement of PCB
Quick Replacement Of PCB With Only 3 Steps:
1. Open front panel.
2. Take off PCB box cover.
3. Take out PCB for replacement.
COMFORTABLE COOLING & HEATING
Comfortable Cooling
Cooling under extreme condition. Keep you cool in scorching summer. Stay cool no matter the temperature. Air-cooled E-box ensures continuous cooling even at 60°C ambient.
Comfortable Heating
Heating under extreme condition. Keep you warm in frozen winter. The TCL compressor is designed to operate efficiently in cold weather. It maintains its heating functionality even when the outside temperature drops to -20°C. Your room temperature remains comfortable even in harsh winter conditions.
Fast Cooling & Heating
Turbo Cooling & Heating. Experience fast cooling with coils down to 18°C within 30s and have warm atmosphere with coils up to 40°C within 60s, the inverter compressor runs at extremely high frequency to output max, capacity and the cooling/warm airflow will blow out as set when you get back home from scorching/freezing outside.
*Features, specs and certifications vary by model and region.
HOTEL MODE
Door Card
The air conditioner is seamlessly integrated with the door card system. When a guest exits the room and removes the door card, the air conditioner automatically switches off. This feature enhances energy efficiency and ensures that the air conditioning system is not running unnecessarily when the room is.
Window Switch
The system is designed to detect open windows. If a window is left open, the advanced system promptly shuts down the air conditioner. This not only conserves energy but also helps maintain the desired indoor temperature by preventing the loss of conditioned air.
Fire Alarm
In the event of a fire alarm, the air conditioner is programmed to automatically power down. This prioritizes safety by ensuring that occupants can exit the building without hindrance from operating air conditioning systems. This feature aligns with safety protocols in emergencies.
Wired Controller
The air conditioning hotel mode is a convenient feature that allows you to control the air conditioner using a wired remote controller. It is especially useful in hotel rooms where guests can easily adjust the temperature and settings according to their preferences.
More Functions Available with The Remote Control Setting Auto Restart
Switch off this function to prevent the air conditioner auto restart from power recovery.Cooling Only or Heating Only
Setting the Cooling only or Heating only help prevent mistake model selection.Filter Replacement Reminder
This function reminder administrator to replace the filter to keep the air clean and save energy.Maximum and Minimum Temperature
The administrator can program the maximum or minimum temperature to limit the setting temperature range, for example, in the summer, set minimum 24°C and maximum 28°C, then the customer only can set 24~28°C, in cooling.
BMS Function
BMS (Building Management System) This feature allows you to integrate and control up to 30 air conditioning units through a single computer. BMS stands for Building Management System, which is a computer-based control system used to monitor and manage various building functions.
FILTER REMINDER
Smart Filter Blockage Reminder
Our air conditioner keeps you informed on filter cleanliness. When the filter is full, the AC displays “CL” and sends a reminder through TCL Home app.
SELF-DIAGNOSIS
Self-diagnosis and Refrigerant Leakage Reminder
Enjoy peace of mind with our AC’s built-in self-check feature! It proactively identifies potential issues, including refrigerant leaks, and notifies you with a code displayed on the control panel. Furthermore, receive real-time notifications directly to your phone. Rest assured knowing that our AC system guarantees safe operation.
TAC-10CSD/KEI2 FULL SPECIFICATIONS
| Horse power | 1HP |
| Power supply (Ph-V-Hz) | 230V~60Hz, 1Ph |
| Control type | Remote |
| Rated cooling capacity (kJ/h) | 10000(2510~11600) |
| CSPF (W/W) | 4.9 |
| Energy Star | 5-Star |
| Moisture removal (Liters/h) | 0.8 |
| Voltage Range (V) | 155~265 |
| Rated current – Cooling (A) | 3.5(1.0~7.0) |
| Rated input – Cooling (W) | 780(220~1200) |
| Max current (A) | 7 |
| Max input (W) | 1200 |
| Refrigerant/Charge (Gram) | R32/300g |
| Indoor air circulation (m³/h) | 550 |
| Indoor fan type | Cross Flow |
| Indoor fan motor type | DC |
| Outdoor fan type | Propeller fan |
| Outdoor fan motor type | DC |
| Connecting Pipe – Gas (Inches) | 3/8” |
| Connecting Pipe – Liquid (Inches) | 1/4” |
| Connecting Wiring (Size x Core number) | 4×1.0mm2 |
| Suitable area (m²) | 9~16 |
| Net dimensions (W x H x D) – Indoor (mm) | 790×275×192 |
| Net dimensions (W x H x D) – Outdoor (mm) | 712×276×459 |
| Net weight – Indoor (kg) | 8 |
| Net weight – Outdoor (kg) | 18.5 |
| Packing dimensions (W x H x D) – Indoor (mm) | 860×345×265 |
| Packing dimensions (W x H x D) – Outdoor (mm) | 765×310×481 |
| Gross weight – Indoor (kg) | 10 |
| Gross weight – Outdoor (kg) | 20.5 |
| Loading Capacity 40HQ with pipe (PCS) | 342 |
TAC-13CSD/KEI2 FULL SPECIFICATIONS
| Horse power | 1.5HP |
| Power supply (Ph-V-Hz) | 230V~60Hz, 1Ph |
| Control type | Remote |
| Rated cooling capacity (kJ/h) | 13000(2860~14700) |
| CSPF (W/W) | 4.92 |
| Energy Star | 5-Star |
| Moisture removal (Liters/h) | 1.2 |
| Voltage Range (V) | 155~265 |
| Rated current – Cooling (A) | 5.8(1.5~13.0) |
| Rated input – Cooling (W) | 1300(220~1550) |
| Max current (A) | 13 |
| Max input (W) | 1550 |
| Refrigerant/Charge (Gram) | R32/360g |
| Indoor air circulation (m³/h) | 600 |
| Indoor fan type | Cross Flow |
| Indoor fan motor type | DC |
| Outdoor fan type | Propeller fan |
| Outdoor fan motor type | DC |
| Connecting Pipe – Gas (Inches) | 3/8” |
| Connecting Pipe – Liquid (Inches) | 1/4” |
| Connecting Wiring (Size x Core number) | 4×1.0mm2 |
| Suitable area (m²) | 15~23 |
| Net dimensions (W x H x D) – Indoor (mm) | 790×275×192 |
| Net dimensions (W x H x D) – Outdoor (mm) | 712×276×459 |
| Net weight – Indoor (kg) | 8.5 |
| Net weight – Outdoor (kg) | 19.5 |
| Packing dimensions (W x H x D) – Indoor (mm) | 860×345×265 |
| Packing dimensions (W x H x D) – Outdoor (mm) | 765×310×481 |
| Gross weight – Indoor (kg) | 10.5 |
| Gross weight – Outdoor (kg) | 21.5 |
| Loading Capacity 40HQ with pipe (PCS) | 342 |
TAC-19CSD/KEI2 FULL SPECIFICATIONS
| Horse power | 2HP |
| Power supply (Ph-V-Hz) | 230V~60Hz, 1Ph |
| Control type | Remote |
| Rated cooling capacity (kJ/h) | 19600(3400~21000) |
| CSPF (W/W) | 5.18 |
| Energy Star | 5-Star |
| Moisture removal (Liters/h) | 1.8 |
| Voltage Range (V) | 155~265 |
| Rated current – Cooling (A) | 9.1(1.6~10.2) |
| Rated input – Cooling (W) | 1900(350~2200) |
| Max current (A) | 10.2 |
| Max input (W) | 2200 |
| Refrigerant/Charge (Gram) | R32/500g |
| Indoor air circulation (m³/h) | 1000 |
| Indoor fan type | Cross Flow |
| Indoor fan motor type | DC |
| Outdoor fan type | Propeller fan |
| Outdoor fan motor type | DC |
| Connecting Pipe – Gas (Inches) | 1/2” |
| Connecting Pipe – Liquid (Inches) | 1/4” |
| Connecting Wiring (Size x Core number) | 4×1.5mm2 |
| Suitable area (m²) | 25~40 |
| Net dimensions (W x H x D) – Indoor (mm) | 920×306×195 |
| Net dimensions (W x H x D) – Outdoor (mm) | 795×305×549 |
| Net weight – Indoor (kg) | 10 |
| Net weight – Outdoor (kg) | 23 |
| Packing dimensions (W x H x D) – Indoor (mm) | 990×380×265 |
| Packing dimensions (W x H x D) – Outdoor (mm) | 835×328×590 |
| Gross weight – Indoor (kg) | 12 |
| Gross weight – Outdoor (kg) | 26 |
| Loading Capacity 40HQ with pipe (PCS) | 260 |
TAC-25CSD/KEI2 FULL SPECIFICATIONS
| Horse power | 2.5HP |
| Power supply (Ph-V-Hz) | 230V~60Hz, 1Ph |
| Control type | Remote |
| Rated cooling capacity (kJ/h) | 26300(5400~28000) |
| CSPF (W/W) | 5.72 |
| Energy Star | 5-Star |
| Moisture removal (Liters/h) | 2.4 |
| Voltage Range (V) | 155~265 |
| Rated current – Cooling (A) | 10.5(1.5~13.0) |
| Rated input – Cooling (W) | 2350(200~2650) |
| Max current (A) | 13 |
| Max input (W) | 2650 |
| Refrigerant/Charge (Gram) | R32/750g |
| Indoor air circulation (m³/h) | 1450 |
| Indoor fan type | Cross Flow |
| Indoor fan motor type | DC |
| Outdoor fan type | Propeller fan |
| Outdoor fan motor type | DC |
| Connecting Pipe – Gas (Inches) | 1/2” |
| Connecting Pipe – Liquid (Inches) | 1/4” |
| Connecting Wiring (Size x Core number) | 4×0.75mm2 |
| Suitable area (m²) | 30~50 |
| Net dimensions (W x H x D) – Indoor (mm) | 1100×333×222 |
| Net dimensions (W x H x D) – Outdoor (mm) | 853×349×602 |
| Net weight – Indoor (kg) | 14 |
| Net weight – Outdoor (kg) | 29 |
| Packing dimensions (W x H x D) – Indoor (mm) | 1165×405×295 |
| Packing dimensions (W x H x D) – Outdoor (mm) | 890×385×628 |
| Gross weight – Indoor (kg) | 17 |
| Gross weight – Outdoor (kg) | 32 |
| Loading Capacity 40HQ with pipe (PCS) | 190 |
































Reviews
There are no reviews yet.